Wireless POINT I/O Adapter
ILX34-AENWG
The ProSoft Technology Wireless POINT I/O Adapter is a high-speed, standards-based 802.11g wireless input/output (I/O) communication adapter offering a convenient wireless alternative for linking Rockwell Automation controllers to distributed process I/O modules. Combining Rockwell Automation's field proven I/O with ProSoft Technology's Integrated Wireless Architecture technology and support, the Wireless POINT I/O Adapter provides users an optimum distributed I/O communication solution.
The Wireless POINT I/O Adapter Add-On Profile (AOP) utilizes the familiar RSLogix 5000 programming environment and connection-based EtherNet/IP protocol to simplify configuring and communicating with POINT I/O racks scattered throughout the process facility. The compact size of POINT I/O systems, when coupled with the Wireless POINT I/O Adapter, make them ideal for collecting data from and controlling moving systems like robots, automated carts, overhead cranes, earthmovers, as well as fixed-position racks in hard-to-reach areas of the process plant.
The Wireless POINT I/O Adapter can be used in networks with RadioLinx Industrial Hotspots or third party 802.11g access points to provide high-speed, low latency 802.11g client communication over widely spaced plant areas. This ability to work with existing standards-based wireless technology protects and leverages the end-users' investment. For security, the Wireless POINT I/O employs 802.11i WPA2 with AES Encryption.
|
Features
|
Benefits
|
|
EtherNet/IP connection-based communication
|
- Connection-based communication for the highest level of integration with Rockwell Automation controllers and software
|
|
Program using RSLogix 5000 version 17 or later and AOP
|
- Simplified integration with a familiar programming environment
- Easy to configure, no special configuration software required
- Integrated web page for wireless configuration
|
|
802.11g client
|
- Standards-based wireless protects investment and allows communication with RadioLinx Industrial Hotspots or 3rd party 802.11g access points
- High-speed, low latency wireless communication
|
|
Supports ProSoft Technology Integrated Wireless Architecture when used with RadioLinx Industrial Hotspots
|
- Optimizes wireless bandwidth through intelligent routing of multicast packets
- Limits loss of I/O messages
|
|
Uses Rockwell Automation POINT I/O modules
|
- Field-proven, cost effective I/O platform
- POINT I/O diagnostic features include channel-level diagnostics, removal and insertion under power
- Many Input/Output types to choose from digital I/O, analog I/O, POINT Guard I/O, RTD, thermocouple, serial-interface for ASCII, and counters
- Easy to add / customize point count - up to 63 POINT I/O modules per adapter
|
Configuration
Both wireless and I/O configuration is done using the ILX34-AENWG Add-On Profile in RSLogix 5000 v17 (or later). Configuration of wireless parameters may be done using the integrated web pages to enable configuration of I/O modules over-the-air.
General Specifications
- Data communication interface via IEEE 802.11g 54Mb Wireless standard
- Configuration interface via 10/100 full/half duplex Cat5 cable
- EtherNet/IP messages encapsulated within standard TCP/UDP/IP protocol
- Half/full duplex 54 Mbps wireless operation
- Communication to and from other POINT I/O modules on the same DIN-rail
- Communication supported by RSLinx software
- I/O configuration via RSLogix 5000 software
- No network scheduling required
- No routing tables required
- Support of connections from multiple controllers simultaneously
Functional Specifications
|
Expansion I/O Capacity
|
|
POINTBus Current Output
|
ILX34-AENWG uses 1.0A, 300 mA available for I/O modules.
Use 1734-EP24DC backplane extension power supplies to extend beyond 300 mA
|
|
Maximum # of Modules
|
63 modules
|
|
Max # of Rack Optimized Connections
|
5 for digital I/O modules only
|
|
Max # of direct connections
|
20
|
Hardware Specifications
|
Power Supply
|
|
Input Voltage
|
24 Vdc nominal, 10-28.8 Vdc range
|
|
Power Consumption
|
10.0 W max @ 28.8 Vdc
|
|
Input Protection
|
Reverse Polarity, Transients
|
|
Isolation Voltage
|
1800 Vdc for 60 sec
|
|
General
|
|
Indicators (RF status)
|
Link, Activity Reused from the wired link/activity bicolor LEDs
|
|
POINTBus Output Current
|
300 mA maximum
|
|
Thermal Dissipation
|
9.5 BTU / hr, maximum
|
|
Dimensions inches (mm)
|
3.0H x 2.16W x 5.25L (76.2H x 54.9W x 133.4L)
|
|
Mass
|
12 oz / 340 grams
|
|
EtherNet Connector
|
RJ-45, Category 5
|
|
Environmental
|
|
Operating Temperature
|
-4 ° F to 131 ° F (-20° C to 55° C)
IEC 60068 - 2 -1 cold
IEC 60068 - 2 -2 dry heat IEC 60068 - 2 -14 thermal shock
|
|
Storage Temp
|
-40° to 85° C
|
|
Relative Humidity
|
5% to 95% RH,
with no condensation IEC 60068-2-30
|
|
Shock
|
30g operating 50g nonoperating IEC 60068-2-27
|
|
Vibration
|
5g 10 to 500Hz IEC 60068-2-6
|
|
ESD Immunity
|
6 kV contact discharge 8 kV air discharge IEC 60068-4-2
|
|
Radiated RF Immunity
|
10V/m 1kHz sine AM Modulation 30MHz to 2GHz
10V/m 200 Hz AM Pulse 50% to 100 % frequencies IEC 60068-4-3
|
|
EFT/B Immunity
|
4kV at 5kHz power ports, 2kV 5.0kHz communication ports IEC 61000-4-5
|
|
Surge Transient Immunity
|
1 kV line-line (DM) and 2 kV line-earth (CM) on comm. Ports
1 kV line-line (DM) and 2 kV line-earth (CM) on power ports IEC 61000-4-5
|
|
Conducted RF Immunity
|
10Vrms 1kHz sine 80% modulation AM 150kHz to 80MHz IEC 61000-4-6
|
|
Emissions
|
CISPR 11 Group 1 Class A
|
|
Enclosure rating
|
None (open style)
|
|
Radio / RF
|
|
Communication standard
|
802.11g
|
|
Security
|
802.11i (WPA2)
|
|
Encryption
|
None, WEP, AES
|
|
RF Power
|
12 dBm (16 mW) without antenna gain - allows up to 6 dBi antenna for ETSI, 100 mW EIRP limited countries
|
|
Antenna connection
|
One RP-SMA connector
|
|
IGMP querying support
|
Use of WDS to support IGMP querying and multicast
|
|
Indoor distance
|
100 meters at 54 Mbps (use RadioLinx Industrial Hotspots radios to extend range)
|
|
Outdoor distance
|
Up to 3 km with high gain, directional antennas and RF line-of-sight
|
|
Enclosure
|
|
Cover
|
Molded plastic, integrated DIN rail clip
|
|
All other components
|
Supplied by Rockwell Automation standard 1734-AENTR parts
|
|
Enclosure Type Rating
|
None (open-style)
|
|
LED Indicators
|
- Link
- Activity
- System Power
- Field Power
- Module Status
- Network Status
- Network Activity
- POINTBus Status
|
|
Performance
|
|
Wireless packets per second
|
Up to 1000
|
|
RSLogix I/O Configuraton Requested Packet Interval, Typical for one adapter per single 802.11 network
|
Allow 20 ms per I/O connection
Example: Set RPI = 100ms for 5 I/O connections
(For recommended RPI using multiple adapters per single network, contact ProSoft Technical Support)
|
Ordering Information
| ILX34-AENWG |
Wireless POINT I/O Adapter |
| |
|
| To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here. |
Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.