Connectivity interfaces for Rockwell Automation ControlLogix (1756) processors.

Product Name

Product Number

'C' Programmable Communications Interface for ControlLogix MVI56-ADM

The MVI56 Application Development Module is a ControlLogix backplane compatible module that allows user-developed 'C' applications to operate on the ControlLogix platform. A great way to speed up custom ASCII data communications or to protect a proprietary algorithm, the ADM is a powerful tool for the ControlLogix platform.

'C' Programmable with Ethernet MVI56-ADMNET

The MVI56 Application Development Communication Module with Ethernet is a ControlLogix backplane compatible module that allows Rockwell Automation ControlLogix processors to interface with Ethernet protocol (Explicit Messaging) compatible devices and hosts. Devices commonly supporting the protocol include Rockwell Automation PLCs, and host HMI systems.

AB-PCCC Communications interface Module for ControlLogix by FieldServer Technologies PS56-PRO-407

The AB_CSP driver implements the Allen Bradley Ethernet protocol commonly referred to as the CSP, using PCCC message structures. The AB_CSP driver allows the SlotServer to transfer data to and from devices over AB_CSP Ethernet protocol. The SlotServer can emulate either a Server or Client. Comes with the standard two-year FieldServer warranty.

BACnet Communication Interface Modules by FieldServer Technologies PS56-BAS-40x, PS56-BAS-073, PS56-BAS-016

The SlotServer ControlLogix BACnet Communication Interfaces allow an Allen Bradley ControlLogix platform to pass data between a ControlLogix PAC and BACnet devices and networks. The BACnet SlotServer can be configured as a BACnet slave or Master enabling exchange of information between BACnet Master devices such as Trane BCU, Alerton Controllers, etc) or BACnet slave devices such as VSD, lighting controls, AC controls, etc. Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module. SlotServer is a flexible communications module that can be configured to communicate to a wide range of protocols found in the extensive FieldServer Technologies library of protocols. The SlotServer is recognized as an input/output module by ControlLogix and has access to processor memory for data transfer between processor and module.

BASIC Module (DB/BAS Compatible) MVI56-BAS

This single-slot module is a powerful solution that allows the large installed base of legacy BASIC programs for the 1771-DB and 1747-BAS modules to be migrated to the ControlLogix platform with minimal effort.

Building Automation Systems (BAS) Communication Interface Modules for ControlLogix by FieldServer Technologies PS56-BAS-xxx

The SlotServer ControlLogix BAS Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and a variety of Building Automation System protocol communications networks. Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module. Comes with the standard two-year FieldServer warranty.

DF1 Half/Full Duplex Master/Slave Communication Interface Module MVI56-DFCM

The MVI56 DF1 Master/Slave Communication Module is a ControlLogix backplane compatible module that allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with DF1 protocol compatible devices and hosts. Devices commonly supporting the protocol include Rockwell Automation PLCs and power monitoring equipment, as well as several other third party devices in the marketplace.

DF1 Half/Full Duplex Master/Slave Communication Module with Reduced Data Block MVI56-DFCMR

The MVI56 DF1 Master/Slave Communication Module with Reduced Data Block is a ControlLogix backplane compatible module that allows Rockwell Automation ControlLogix I/O compatible processors to easily interface with DF1 protocol compatible devices and hosts. Devices commonly supporting the protocol include Rockwell Automation PLCs and power monitoring equipment, as well as several other third party devices. This module uses a small I/O data area for data transfer between the module and the ControlLogix processor, making it ideal for applications with the module in a remote rack, connected to the processor by ControlNet or EtherNet/IP.

DH-485 Communication Module for Remote Chassis MVI56-DH485R

The MVI56 DH-485 Communication Module for Remote Chassis allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with other DH-485 protocol compatible devices. Compatible devices include not only Rockwell Automation PLCs (which support the DH-485 protocol) but also a wide assortment of end devices. This module uses a small I/O data area for data transfer between the module and the ControlLogix processor, making it ideal for ControlNet or Ethernet applications with the module in a remote rack.

DH485 Communication Interface Module for ControlLogix MVI56-DH485

The MVI56 DH485 Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with other DH485 protocol compatible devices. Compatible devices include not only Rockwell Automation PLCs (which support the DH485 protocol) but also a wide assortment of end devices.

DNP 3.0 Master/Slave Communications Interface Module MVI56-DNP

The MVI56 DNP 3.0 Master/Slave Communication Module is a single slot, backplane compatible DNP 3.0 interface solution for the Rockwell Automation ControlLogix platform. This module provides highly configurable support of both DNP 3.0 Master and Slave implementations (level 2 minimum), allowing the many SCADA and field devices supporting the DNP protocol to be integrated into the powerful ControlLogix platform.

DNP 3.0 over Ethernet Server Communications Interface Module MVI56-DNPSNET

The MVI56 DNP 3.0 Server Ethernet Communications Module supports the implementation of the DNP 3.0 (Distributed Network Protocol) over Ethernet, allowing ControlLogix processors to easily communicate with host systems supporting the protocol. The module supports DNP Subset Level 2 features and some Level 3 features.

FA Control Network Enhanced Communication Module MVI56E-FLN

The MVI56E-FLN FA Control Network Enhanced communication module is a single-slot solution that allows ControlLogix-compatible processors to easily interface with other FL-net protocol devices. The module is certified for use with FL-net version 2.00 (OPCN-2) for the standard FA control network, as defined by JEMA (The Japan Electrical Manufacturers Association). The MVI56E-FLN module acts as a gateway between the FL-net network and the ControlLogix backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the FL-net network. The MVI56E-FLN module accepts commands to control and monitor the data stored in its databases. This data is passed between the module and the ControlLogix processor over the backplane for automation and control applications.

Fire Alarm Control Panel Communication Interface Module for ControlLogix by FieldServer Technologies PS56-FIR-xxx

The SlotServer ControlLogix FIR Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and a variety of Fire Alarm Control Panel (FACP) protocol communications networks. Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module. SlotServer provides serial and Ethernet ports to enable ControlLogix interface to any of the FACP protocols available in the FieldServer driver library including Simplex, Notifier, EST (GE) and more, Comes with the standard two-year FieldServer warranty

Fisher PROVOX In-Chassis Module Fisher PROVOX In-Chassis Module

The PROVOX module allows an Allen-Bradley ControlLogix processor to control Fisher PROVOX I/O devices. This module allows a phased migration approach to be used when upgrading or replacing the PROVOX controllers. The gateway provides automatic creation of the PROVOX network scan-list and generates the associated RSLogix 5000 tags reducing engineering effort. Monitor mode allows verification of your conversion logic using live I/O data without impacting the running legacy system. Once the new PAC is commissioned the legacy I/O can be upgraded one module or one rack at a time as scheduled downtime is available. This module minimizes the risk of excessive downtime when upgrading legacy control systems.

Garvens Remote Control Checkweigher Interface Module MVI56-GRCM

The MVI56 Garvens Remote Control Checkweigher Interface Module allows ControlLogix I/O compatible processors to interface easily with Garvens Checkweighers that use Garvens Remote Control (GARECO) serial protocol. The module offers two application serial ports, providing connectivity for one GARECO device per port.

GE Ethernet Global Data Communication Module MVI56-EGD

The Ethernet Global Data (EGD) module can be used to interface many different protocols with EGD devices. The EGD driver supports both the producer/consumer service port (18246) and the command service port (7937) using the UDP protocol over an IP network. The user defines the data to be produced and consumed in a configuration file downloaded to the module.

Generic ASCII Ethernet Communications Interface Module MVI56-GEC

The MVI56 Generic ASCII Ethernet Interface module is designed to allow ControlLogix processors to interface easily with ASCII devices using the TCP/IP protocol and the ControlLogix processor. Compatible devices may be either ASCII instruments with Ethernet built-in or Ethernet connection via a thin server to the existing ASCII device.

Generic ASCII Serial Enhanced Communication Module MVI56E-GSC / GSCXT

The Generic ASCII Serial Enhanced Communication Modules allow Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to easily interface with serial devices using non-specific ASCII character text string or byte value serial communication protocols. MVI56E-GSC enhancements include local and remote diagnostics through the module's Ethernet port, and CIPconnect technology for bridging through Rockwell Automation ControlNet and EtherNet/IP networks. The module is a single-slot, backplane-compatible solution. Each port is capable of sending and receiving large ASCII character strings or byte streams of up to 4096 characters or bytes. Many different serial communication devices can be integrated into the ControlLogix platform by building upon the sample ladder logic provided for this module. The MVI56E-GSC and MVI56E-GSCXT are functionally the same. The MVI56E-GSC is designed for standard process applications. The MVI56E-GSCXT is designed for the Logix-XT™ control platform, allowing it to operate in extreme environments. It tolerates higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions.

HART Multi-drop Communications Interface Module MVI56-HART

The MVI56 HART Multidrop Master Communication Module is a ControlLogix backplane-compatible module that allows ControlLogix processors to interface easily with HART compatible devices. Devices commonly supporting the protocol include pressure, temperature, flow transmitters, as well as other similar instruments commonly found in the process (and other) industry. HART® is a registered trademark of the HART Communication Foundation.

Honeywell DE Master Communications Interface Module MVI56-DEM

The MVI56 DE Master Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with Honeywell DE instruments. Compatible devices include a large array of field devices including pressure, temperature, metering and many other instruments.

Honeywell IPC-620 In-Chassis Module Honeywell IPC-620 In-Chassis Module

The Honeywell IPC module allows an Allen-Bradley ControlLogix processor to control Honeywell IPC 620 I/O devices. This module allows a phased migration approach to be used when upgrading or replacing Honeywell’s SLM 621-9939 Scanners. This In-chassis module provides automatic detection of the IPC I/O racks and modules. After the direction of the I/O cards has been entered the associated RSLogix 5000 tags can be auto generated significantly reducing engineering effort. Monitor mode allows verification of your conversion logic using live I/O data without impacting the running legacy system. Once the new processor is commissioned the legacy I/O can be upgraded one module or one rack at a time as scheduled downtime is available. This module minimizes the risk of excessive downtime when upgrading legacy control systems

IEC 60870-5-101 Master Communication Module for ControlLogix MVI56-101M

The MVI56 IEC 60870-5-101 Master Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with IEC 60870-5-101 slave (controlled unit) devices.

IEC 60870-5-101 Slave Communication Module MVI56-101S Edition 2

The IEC 60870-5-101 Slave Serial Communication Module, Edition 2, allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with IEC 60870-5-101 protocol compatible hosts. The module's two powerful and highly-configurable redundant ports allow the many SCADA host systems supporting the IEC protocol to be integrated into the ControlLogix platform. The MVI56-101S Edition 2 Slave module is designed to address the application where a host systems using the IEC 60870-5-101 protocol must communicate with a ControlLogix processor. This lastest version offers IEC 60870-5-101Edition 2 protocol features, such as additional datatypes and additional Causes of Transmission (COT) support.

IEC 60870-5-103 Master Communication Module MVI56-103M

The MVI56 IEC 60870-5-103 Master Communication Module allows Rockwell Automation ControlLogix backplane I/O compatible processors to interface easily with IEC 60870-5-103 compatible devices. Devices commonly supporting the protocol include relays, breakers, sub-station Communication Modules and other serial communication devices used in power monitoring.

IEC 60870-5-103 Master Communication Module with Reduced Data Block MVI56-103MR

The MVI56 IEC 60870-5-103 Master Communication Module with Reduced Data Block allows Rockwell Automation ControlLogix backplane I/O compatible processors to interface easily with IEC 60870-5-103 compatible devices. Devices commonly supporting the protocol include relays, breakers, sub-station Communication Modules and other serial communication devices used in power monitoring. This module uses a small I/O data area for data transfer between the module and the ControlLogix processor, making it ideal for ControlNet applications.

IEC 60870-5-104 Server Communication Module With Edition 2 Support MVI56-104S

The MVI56 IEC 60870-5-104 Server Communication Module allows ControlLogix backplane I/O compatible processors to interface easily with IEC 60870-5-104 protocol-compatible hosts.

In-Rack Industrial PC for ControlLogix PC56-CE, PC56-XP

The PC56 is an industrial in-rack PC for the ControlLogix platform. Driven by a powerful 500MHz AMD processor, the module serves as a powerful platform for those applications requiring or benefiting from custom development. A direct connection to the ControlLogix backplane gives the PC56 read and write connectivity to the CLX 55XX processor data tables. This direct connection between the CLX data tables and the PC56's ability to support Serial and Ethernet communications makes the PC56 an ideal solution for today's analytical and data centric applications. The PC56 is a high-performance tool capable of supporting those needing to meet today's IT and e-commerce requirements, or simply those that need a powerful processing engine to augment their ControlLogix solution.

In-Rack PC with Data Historian for ControlLogix PC56-HIST-500LX, PC56-HIST-1500LX, PC56-HIST-3000LX, PC56-HIST-5000LX

The in-rack PC with Data Historian is an industrial PC for the ControlLogix (CLX) platform that provides high-speed, time series, data storage and retrieval with both local and remote CLX processors. The in-rack PC with Data Historian allows customers to perform data collection in an efficient, distributed, and cost-effective fashion. In addition, the PC56-HIST Historian is the ideal solution for those customers who want to implement an electronic data storage solution while maintaining compliance with FDA Regulation 21 CFR Part 11.

In-Rack PC with OPC Server, CLX PC56-OPC

The PC56 with OPC Server allows you to access data from a ControlLogix PLC directly across the backplane, and connect to an OPC Client. The PC56-OPC is an industrial PC for the ControlLogix platform that provides high speed communication with both local and remote ControlLogix processors. The PC56-OPC allows users to communicate with ControlLogix processors in an efficient, distributed, and cost-effective fashion.

In-Rack PC with Wonderware SuiteLink-DAServer, CLX PC56-SLS

The PC56 with SLS-DAServer (Data Access Server) allows you to access data from a ControlLogix PLC directly across the backplane, and then communicate via SuiteLink, DDE, or FastDDE to local or remote Application Objects. The PC56-SLS is an industrial PC for the ControlLogix platform that provides high speed communication with both local and remote ControlLogix processors. The PC56-SLS allows users to communicate with ControlLogix processors in an efficient, distributed, and cost-effective fashion. The PC56-SLS includes a graphical interface called Archestra SMC (Management Console) for easy configuration and diagnostic support.

inRAx Message Manager for Industrial Communication ILX56-MM

The ProSoft Technology inRAx Message Manager is a single-slot solution that connects and transfers Factory and Plant Process Automation monitoring and control data between islands of automation across diverse platforms, networks and protocols. The inRAx Message Manager is a data transfer engine for the ControlLogix 1756 platform, supporting Rockwell Automation Programmable Logic Controller (PLC) and Programmable Automation Controller (PAC) network protocols, as well as platforms and devices that use Siemens Industrial Ethernet and Modbus TCP/IP protocols. The ILX56-MM reduces the engineering effort required to coordinate data transfers between multiple control systems in Factory and Plant Automation applications. The Message Manager streamlines data connection and transfer operations by enabling PLC/PAC data exchanges without the need for additional message-specific PLC programming.

Johnson Controls Metasys N2 Slave Interface Module for ControlLogix MVI56-N2

The MVI56 Johnson Controls Metasys Slave Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with other Johnson Controls N2 master devices.

Johnson Controls Metasys N2 Systems Communication Module for ControlLogix by FieldServer Technologies PS56-BAS-019

Part Number: PS56-BAS-019 The SlotServer ControlLogix Metasys N2 by JCI Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and Johnson Controls Metasys N2 networks. The Metasys N2 SlotServer can be configured as a Metasys Slave or Master enabling exchange of information between Metasys Master devices such as NCM, N-30, NAE or NIE) or Metasys Slave devices such as UNT, VMA, DX9100, VAV or AHU. Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module. SlotServer is a flexible communications module that can be configured to communicate to a wide range of protocols found in the extensive FieldServer Technologies library of protocols. The SlotServer is recognized as an input/output module by ControlLogix and has access to processor memory for data transfer between processor and module. Comes with the standard two-year FieldServer warranty

Limitorque Valve Communications Interface Module MVI56-LTQ

The MVI56 Limitorque Valve Actuator Master Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with Limitorque Valve Actuators and other Limitorque protocol compatible devices.

Liquid and Gas Flow Computer for ControlLogix MVI56-AFC

The Liquid & Gas Flow Computer Module is designed as an integrated component for the ControlLogix® systems to measure hydrocarbon gases or liquids with accuracy and precision. The module calculates flow rates and accumulated totals of volumes, mass, and energy (heating value) for the specified liquids and gases. Selected calculated results are available in the processor memory for use in the application ladder program or by a SCADA host via the three front panel Modbus serial ports. The flow computer and the ControlLogix system has been approved by Industry Canada – Measurement for custody transfer measurement of hydrocarbon gases. The module can be configured and monitored for all the functions using the AFC Manager utility.

LonWorks Communication Interface Module for ControlLogix by FieldServer Technologies PS56-LON-000

Part Number Protocol Version Part Number Protocol Version
PS56-LON-000 LonWorks for Generic SNVTs PS56-LON-001 LonWorks for Configurable SNVTs
The SlotServer LonWorks Open Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and a standard LonWorks communications network. The SlotServer Module provides a standard generic profile in LonWorks that allows most of the more common Standard Network Variable Types (SNVT’s) to be bound to the SlotServer for data transfer. Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. SlotServer provides serial and Ethernet ports to enable ControlLogix interface to any of the many protocols available in the FieldServer driver library including BACnet, JCI Metasys, and a wide range of proprietary and legacy protocols used in the building automation, fire alarm panels and process control industries. Comes with the standard two-year FieldServer warranty.

MDA Scientific CM4 Master Module MVI56-MDA4

The MVI56 MDA Scientific CM4 Gas Analyzer Master Module allows Rockwell Automation ControlLogix processors to interface easily as a host with MDA Scientific CM4 gas monitoring hardware (See MVI56-MDA16 for a System 16 solution).

Modbus Master/Slave Enhanced Communication Module MVI56E-MCM, MVI56E-MCMXT

The MVI56E Modbus Master/Slave Enhanced Communication Modules (MVI56E-MCM, MVI56E-MCMXT) allow Rockwell Automation ControlLogix processors to easily interface with devices using the Modbus RTU/ASCII serial communication protocol. The MVI56E-MCM and MVI56E-MCMXT act as input/output modules on the ControlLogix backplane, making Modbus data appear as I/O data to the processor. Data transfer to and from the processor is asynchronous from the communications on the Modbus network. Two independently-configurable serial ports can operate on the same or different Modbus networks. Each port can be configured as a Modbus Master or Slave, sharing the same user-controlled 5000-word database. The two modules are functionally the same. The MVI56E-MCM is designed for standard process applications. The MVI56E-MCMXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments, at higher operating temperatures, with a conformal coating to protect it from harsh or caustic conditions.

Modbus Master/Slave Enhanced Communications Interface Module with Reduced Data Block MVI56E-MCMR

The Enhanced Modbus Master/Slave Communication Module with Reduced Data Block (MVI56E-MCMR) allows Rockwell Automation ControlLogix processors to easily interface with devices using the Modbus RTU/ASCII serial communications protocol. Compatible devices include a wide variety of instruments, process measurement devices, popular brands of programmable logic controllers (PLCs) and programmable automation controllers (PACs). The Enhanced Modbus Master/Slave Communication Module with Reduced Data Block acts as an input/output module on the ControlLogix backplane, making Modbus data appear as I/O data to the processor. Backplane data transfers to and from the processor are asynchronous from communications on the Modbus network. Two independently-configurable serial ports can operate on the same or different Modbus networks. Each port can be configured as a Modbus Master or Slave, sharing the same user-controlled 5000-word database.

Modbus Plus Communication Module, Single Port With Redundant Media Connectors MVI56-MBP

The MVI56 Modbus Plus Communication Module allows ControlLogix processors to easily interface with Modbus Plus devices. The Modbus Plus module is designed with both Peer-to-Peer polling and Global Data support, offering convenient options for connecting to other Modbus Plus devices (Modicon processors and many others).

Modbus TCP/IP Client/Server Enhanced Communication Module MVI56E-MNET & MVI56E-MNETXT

The MVI56E Modbus TCP/IP Client/Server Enhanced Communication Module allows Rockwell Automation ControlLogix processors to interface easily with Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP/IP-compatible instruments and devices. MVI56E enhancements include local and remote configuration and diagnostics through the module’s Ethernet port, and CIPconnect technology for bridging through Rockwell Automation ControlNet and EtherNetIP networks. The Modbus TCP/IP Client/Server Enhanced Communication Module and Modbus TCP/IP Client/Server Enhanced Communication Module for Logix-XT are functionally the same. The Modbus TCP/IP Client/Server Enhanced Communication Module is designed for standard process applications. The Modbus TCP/IP Client/Server Enhanced Communication Module for Logix-XT is designed for the Logix-XT control platform, allowing it to operate in extreme environments. It tolerates higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions.

Modbus TCP/IP Client/Server Enhanced Communication Module with Reduced Data Block MVI56E-MNETR

The Modbus TCP/IP Client/Server Enhanced Communication Module with Reduced Data Block allows Rockwell Automation ControlLogix processors to interface easily with Modbus TCP/IP-compatible devices, such as Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP/IP-compatible instruments and devices. The MVI56E-MNETR uses a reduced Input/Output (I/O) data image block size for transferring data between itself and a ControlLogix processor. This makes it ideal for remote rack applications using ControlNet or EtherNet/IP process networks. The module also works well for applications that require redundant ControlLogix processors. MVI56E-MNETR enhancements include local and remote configuration and diagnostics through the module's Ethernet port, and CIPconnect technology for bridging through Rockwell Automation ControlNet and EtherNetIP networks.

Modbus TCP/IP Multi-Client Enhanced Communication Module With Reduced Data Block MVI56E-MNETCR

The MVI56E Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis (MVI56E-MNETCR) allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCP/IP server-compatible instruments and devices. The multi-Client module improves performance when controlling multiple servers on a Modbus TCP/IP network, by supporting up to 30 Clients. MVI56E enhancements include configuration and management through the module Ethernet port, and CIPconnect technology for bridging through ControlNet and EtherNet/IP networks. This module uses a small I/O data image for transfer of data between the module and the ControlLogix processor, making it ideal for ControlNet or Ethernet applications with the module in a remote rack.

Modbus TCP/IP Multi-Client Enhanced Communications Module MVI56E-MNETC

The MVI56E Modbus TCP/IP Multi-Client Enhanced Communication Module allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCP/IP server-compatible instruments and devices. The multi-Client module improves performance when controlling multiple servers on a Modbus TCP/IP network, by supporting up to 30 Clients. MVI56E enhancements include configuration and management through the module Ethernet port, and CIPconnect technology for bridging through ControlNet and EtherNet/IP networks.

PROFIBUS DP Slave MVI56-PDPS

The MVI56 PROFIBUS DP Slave Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with a PROFIBUS DP Master device.

PROFIBUS DP-V1 Master Communication Module for ControlLogix MVI56-PDPMV1

The PROFIBUS DP-V1 Master Communication Module is a powerful communication interface for ControlLogix platform processors. Developed under license from Rockwell Automation, the module incorporates proprietary backplane technology that enables powerful data exchange with ControlLogix processors.

Siemens 3964R Network Module for ControlLogix MVI56-S3964R

The MVI56-S3964R Protocol module from ProSoft Technology allows point-to-point communication between a ControlLogix controller and a partner with 3964R (with or without RK512) communication capability.